BICARBON FAMILY
Many options for many benefits
BICARBON SLIMLINE

Implantation Consideration
- A partially supra-annular solution when in need of larger orifice areas compared to intra-annular valves3
- Orientation of the implanted valve facilitated by a Polyacetal sleeve mounted inside the sewing cuff, which maintains torque at a constant level
- Three orientation markers for suture spacing
- Soft, pliable cuff for easy handling and better conformity to the patient’s annulus
Clinical Consideration
- Special sizers allow surgeon to assess position of valve within sinus area and clearance of coronaries before implantation
- Advanced design allows to achieve a laminar blood flow that minimizes the risk of thrombus formation
- Very low valve-related adverse events
- Proven safety and durability
Valve Placement in-situ

CARBOMEDICS FAMILY
Bileaflet mechanical heart valves
CARBOMEDICS TOP HAT
Implantation Consideration
- Totally supra-annular placement
– provides an advantage of 1 to 2 sizes over intra-annular valves
– facilitates double valve replacement procedure
- The lock wire, connecting the housing and the Titanium stiffening ring, allows for rotatability in-situ
- Three orientation markers for suture spacing
- Special sizers allow Surgeon to assess position of valve within sinus area and clearance of coronaries before implantation
Clinical Consideration
- Size upgrades provide improved valve hemodynamics
- Totally supra-annular design allows a 100% orifice to annulus match, maximizing the orifice available to blood flow
- Alternative to aortic root enlargement
- Low profile housing minimizes interferences with the coronary ostia
- Titanium stiffening ring minimizes the possibility of leaflet lockup or escape
- Proven reliable structural stability
- Very low valve-related adverse events
Valve Placement in-situ

CARBOMEDICS REDUCED

Implantation Consideration
- The lock wire, connecting the housing and the Titanium stiffening ring, allows for rotatability in-situ
- Orientation markers provide easy visual suture positioning (except for Orbis)
- Carbomedics Reduced has a smaller and pliable sewing cuff with respect to the Standard model. This design was conceived for improved seating in a smaller annulus or small root.
Clinical Consideration
- Low profile housing minimizes interferences with the coronary ostia
- Titanium stiffening ring minimizes the possibility of leaflet lockup or escape
- Proven reliable structural stability
- Very low valve-related adverse events
Valve Placement in-situ

CARBOMEDICS CARBO-SEAL
Implantation Consideration
• Pliable, cork-shaped sewing cuff conforms to annulus, designed to minimize potential paravalvular leaks
• Graft material resists fraying and quickly seals suture holes, minimizing bleeding
• Easier handling and suturing in comparison to bulkier velour materials
• Ultra-low porosity fabric and gelatin sealing result in less leakage, weeping and blushing
• Titanium stiffening ring allows rotatability in-situ
• Orientation markers provide easy visual suture positioning
Clinical Consideration
• Graft is infused with minimally crosslinked gelatin that does not alter the healing process, encouraging a secure neo-intimal attachment with reduced inflammatory response
• Collagen gel hydrolyzes within 14 days
• Full-sized standard aortic valve provides favorable hemodynamics
• Very low rate of thromboembolic events
• Titanium stiffening ring minimizes the possibility of leaflet lockup or escape
Valve Placement in-situ